Mineral Profile of Children’s Fast Food Menu Samples
2017
Abstract Children’s fast food menus, including hamburgers served with french fries, dessert, and a soft drink, were analyzed to obtain the mineral profile of trace elements. The developed analytical methodology involved sample digestion under pressure inside a microwave oven with a mixture of HNO3 and H2O2 and inductively coupled plasma-optical emission spectrometry. The method was validated by carrying out the analysis of certified reference materials (NIST 1570a spinach leaves, NCS ZC73016 chicken, and NIST 1568a rice flour) and using recovery experiments. Repeatability was verified by analyzing replicate samples. Twenty-six elements were studied, 12 of which—aluminum, barium, calcium, co…
Determination of mercury at picogram level in natural waters with inductively coupled plasma mass spectrometry by using 3D printed metal scavengers
2019
The determination of ultra-trace concentrations of Hg in natural water samples via preconcentration using 3D printed metal scavenger technique followed by inductively coupled plasma mass spectrometry (ICP-MS) was developed. The determination of Hg in certified reference material ERM-CA615 (groundwater) was performed with high accuracy and precision resulting in recovery of 100 ± 3% and RSD <2.5%, respectively. Selective laser sintering (SLS) 3D printing was used to fabricate the scavengers using a mixture of polyamide-12 powder with thiol-functionalized silica. The preconcentration procedure is based on the adsorption of Hg on the scavenger and followed by elution of the preconcentrated Hg …
A comparative study on sample preparation procedures for supplementary foods by ICP-OES: Green chemistry considerations
2015
An inductively coupled plasma optical emission (ICP-OES) method was developed for the simultaneous determination of major, minor and trace elements in food. Preliminary studies focused on selecting suitable operational conditions in order to provide the highest sensitivity and to maximize the number of analytes to be determined without spectral or matrix interference. Ruthenium and rhenium were evaluated as internal standards and samples were analyzed at different dilution levels. Furthermore, a comparative study was carried out by using three sample digestion methods, microwave-assisted digestion with HNO3/H2O2, dry ashing and dry ashing with Mg(NO3)2/MgO as an ashing aid. Adequate precisi…
Isotope dilution mass spectrometry as a calibration method for the analysis of trace elements in powder samples by LA-ICP-MS
2003
The applicability of the isotope dilution (ID) technique for trace element determinations in powdered solid samples by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is demonstrated. LA-ICP-IDMS combines the advantage of the isotope dilution technique as a definitive method with the powerful capability of LA-ICP-MS for a fast and direct multi-element analysis of solid samples. LA-ICP-IDMS therefore allows matrix-matched quantification of element concentrations without any external standard, which is not possible by other calibration strategies used in LA-ICP-MS, up to now. The sample preparation effort is kept minimal and consists of an addition of the corresponding…
Analytical capabilities of high performance liquid chromatography – Atmospheric pressure photoionization – Orbitrap mass spectrometry (HPLC-APPI-Orbi…
2015
A new analytical method was established and validated for the analysis of 27 brominated flame retardants (BFRs), including so called "emerging" and "novel" BFRs (EBFRs and NBFRs) in fish samples. High performance liquid chromatography (HPLC) coupled to Orbitrap mass spectrometry (Orbitrap-MS) employing atmospheric pressure photoionization (APPI) interface operated in negative mode was used for the identification/quantitation of contaminants. HPLC-Orbitrap-MS analysis provided a fast separation of selected analytes within 14 min, thus demonstrating a high throughput processing of samples. The developed methodology was tested by intralaboratory validation in terms of recovery, repeatability, …
Recovering bronze metallurgy from archaeological artefacts for the production of reference materials in conservation science
2007
The production of reference Cu-based alloys is the first step of an original experimental protocol to be used in the field of conservation and restoration of metal artefacts. The production of these synthetic alloys has a double value. They can be used both as suitable substitutes of unique archaeological pieces for testing new materials and methods for conservation, and as guidelines for contemporary metal production. We report on a research activity focused on the recovery of the ancient production techniques from the investigation of archaeological copper-based artefacts. The chemical, physical and metallurgical characterization of several Cu-based artefacts, found in different Italian a…
Towards the development of a fossil bone geochemical standard: An inter-laboratory study
2007
Ten international laboratories participated in an inter-laboratory comparison of a fossil bone composite with the objective of producing a matrix and structure-matched reference material for studies of the bio-mineralization of ancient fossil bone. We report the major and trace element compositions of the fossil bone composite, using in-situ method as well as various wet chemical digestion techniques. For major element concentrations, the intra-laboratory analytical precision (%RSDr) ranges from 7 to 18%, with higher percentages for Ti and K. The %RSDr are smaller than the inter-laboratory analytical precision (%RSDR; 100% was found for the high field strength elements (Hf, Th, Zr, Nb). The…
Validated fast procedure for trace element determination in basil powder
2011
Abstract An inductively coupled plasma optical emission spectroscopic (ICP-OES) method has been developed and fully validated for trace element determination in basil samples. The method involves the previous sample digestion, under pressure, with a mixture of HNO 3 , HCl and H 2 O 2 inside a microwave oven, 42 elements were studied and 33 elements (Al, As, Ba, Ca, Cr, Co, Cu, Fe, Pb, Li, Mg, Mn, Mo, Ni, K, Se, Na, Sr, Tl, Ti, V, Zn, Sc, Y, La, Ce, Nd, Tb, Ho, Er, Tm, Yb, Lu) were determined quantitatively in basil leaves obtained from Morocco and Spain. The method provided recovery percentages from 89% to 113% for spiked concentrations at mg kg −1 and μg kg −1 . Accurate results were found…
Double Laser LIBS and micro-XRF spectroscopy applied to characterize materials coming from the Greek-Roman theater of Taormina
2009
The laser-induced breakdown spectroscopy (LIBS) is an applied physical technique that has shown, in recent years, its great potential for rapid qualitative analysis of materials. The possibility to implement a portable instrument that perform LIBS analysis makes this technique particularly useful for in situ analysis in the field of cultural heritages. The aim of this work is to compare the results, obtained by LIBS measurements with X-Ray Fluorescence (XRF) ones, on calcareous and refractory materials coming from the Greek-Roman theater of Taormina. Calibration curves for LIBS and XRF were obtained by measuring certified reference materials and using them as standards. LIBS measurements we…
Development of standard operation procedures for the manufacture of n-octadecyl bonded silicas as packing material in certified reference columns for…
2004
The development of standard operation procedures for the manufacture of a n-octadecyl bonded spherical silica packing from partially condensed tetraethoxysilane as silica source is described. The synthesis comprises five intermediate products and six synthesis steps which were examined according to their reproducibility and robustness. The results led to the optimisation of the manufacturing process for a n-octadecyl bonded silica. Correlations were drawn between the dynamic viscosity of the poly(ethoxy)siloxane (PES), the synthesis parameters, the resulting pore structural properties and particle size distribution of the silicas. Validated procedures were developed to manufacture spherical…